{"product_id":"siemens-6sl3000-0he21-0aa0-line-reactor-55kw","title":"Siemens 6SL3000-0HE21-0AA0","description":"\u003ch2 data-start=\"400\" data-end=\"473\"\u003e\u003cstrong data-start=\"403\" data-end=\"473\"\u003eSiemens 6SL3000-0HE21-0AA0\u003c\/strong\u003e\u003c\/h2\u003e \u003ch3 data-start=\"475\" data-end=\"493\" style=\"margin-top:24px;\"\u003e\u003cstrong data-start=\"479\" data-end=\"491\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"494\" data-end=\"835\"\u003eThe Siemens 6SL3000-0HE21-0AA0 is a SINAMICS line reactor designed for use with G120 frequency converters. It supports 3-phase 400 V systems up to 55 kW, reducing harmonic distortion, improving power quality, and protecting the input circuitry of the drive. Ideal for industrial environments that demand increased reliability and efficiency.\u003c\/p\u003e \u003ch3 data-start=\"837\" data-end=\"857\" style=\"margin-top:24px;\"\u003e\u003cstrong data-start=\"841\" data-end=\"857\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e \u003cul data-start=\"859\" data-end=\"1156\"\u003e \u003cli data-start=\"859\" data-end=\"901\"\u003e \u003cp data-start=\"861\" data-end=\"901\"\u003eLine reactor for SINAMICS G120 systems\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"902\" data-end=\"934\"\u003e \u003cp data-start=\"904\" data-end=\"934\"\u003eRated for 55 kW applications\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"935\" data-end=\"962\"\u003e \u003cp data-start=\"937\" data-end=\"962\"\u003e3-phase 400 V operation\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"963\" data-end=\"1003\"\u003e \u003cp data-start=\"965\" data-end=\"1003\"\u003eReduces harmonics and voltage spikes\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1004\" data-end=\"1048\"\u003e \u003cp data-start=\"1006\" data-end=\"1048\"\u003eExtends the lifespan of drive components\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1049\" data-end=\"1081\"\u003e \u003cp data-start=\"1051\" data-end=\"1081\"\u003eImproves system power factor\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1082\" data-end=\"1113\"\u003e \u003cp data-start=\"1084\" data-end=\"1113\"\u003eDIN rail or panel mountable\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1114\" data-end=\"1156\"\u003e \u003cp data-start=\"1116\" data-end=\"1156\"\u003ePassive cooling for maintenance-free use\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"1158\" data-end=\"1190\" style=\"margin-top:24px;\"\u003e\u003cstrong data-start=\"1162\" data-end=\"1190\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cul data-start=\"1192\" data-end=\"1567\"\u003e \u003cli data-start=\"1192\" data-end=\"1232\"\u003e \u003cp data-start=\"1194\" data-end=\"1232\"\u003e\u003cstrong data-start=\"1194\" data-end=\"1211\"\u003eSiemens Code:\u003c\/strong\u003e 6SL3000-0HE21-0AA0\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1233\" data-end=\"1267\"\u003e \u003cp data-start=\"1235\" data-end=\"1267\"\u003e\u003cstrong data-start=\"1235\" data-end=\"1252\"\u003eProduct Type:\u003c\/strong\u003e Line reactor\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1268\" data-end=\"1294\"\u003e \u003cp data-start=\"1270\" data-end=\"1294\"\u003e\u003cstrong data-start=\"1270\" data-end=\"1286\"\u003eRated Power:\u003c\/strong\u003e 55 kW\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1295\" data-end=\"1327\"\u003e \u003cp data-start=\"1297\" data-end=\"1327\"\u003e\u003cstrong data-start=\"1297\" data-end=\"1315\"\u003eInput Voltage:\u003c\/strong\u003e 3AC 400 V\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1328\" data-end=\"1361\"\u003e \u003cp data-start=\"1330\" data-end=\"1361\"\u003e\u003cstrong data-start=\"1330\" data-end=\"1350\"\u003eFrequency Range:\u003c\/strong\u003e 50–60 Hz\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1362\" data-end=\"1408\"\u003e \u003cp data-start=\"1364\" data-end=\"1408\"\u003e\u003cstrong data-start=\"1364\" data-end=\"1379\"\u003eInductance:\u003c\/strong\u003e Optimized per power rating\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1409\" data-end=\"1447\"\u003e \u003cp data-start=\"1411\" data-end=\"1447\"\u003e\u003cstrong data-start=\"1411\" data-end=\"1428\"\u003eInstallation:\u003c\/strong\u003e Cabinet mounting\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1448\" data-end=\"1490\"\u003e \u003cp data-start=\"1450\" data-end=\"1490\"\u003e\u003cstrong data-start=\"1450\" data-end=\"1469\"\u003eCooling Method:\u003c\/strong\u003e Natural convection\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1491\" data-end=\"1521\"\u003e \u003cp data-start=\"1493\" data-end=\"1521\"\u003e\u003cstrong data-start=\"1493\" data-end=\"1514\"\u003eProtection Class:\u003c\/strong\u003e IP00\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1522\" data-end=\"1567\"\u003e \u003cp data-start=\"1524\" data-end=\"1567\"\u003e\u003cstrong data-start=\"1524\" data-end=\"1550\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +40 °C\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"1569\" data-end=\"1589\" style=\"margin-top:24px;\"\u003e\u003cstrong data-start=\"1573\" data-end=\"1589\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e \u003cul data-start=\"1591\" data-end=\"1798\"\u003e \u003cli data-start=\"1591\" data-end=\"1636\"\u003e \u003cp data-start=\"1593\" data-end=\"1636\"\u003eInput protection for SINAMICS G120 drives\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1637\" data-end=\"1682\"\u003e \u003cp data-start=\"1639\" data-end=\"1682\"\u003eHarmonic mitigation in industrial systems\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1683\" data-end=\"1721\"\u003e \u003cp data-start=\"1685\" data-end=\"1721\"\u003eMachine tools and conveyor systems\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1722\" data-end=\"1758\"\u003e \u003cp data-start=\"1724\" data-end=\"1758\"\u003ePump and fan motor drive systems\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1759\" data-end=\"1798\"\u003e \u003cp data-start=\"1761\" data-end=\"1798\"\u003eGeneral-purpose industrial automation\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"1800\" data-end=\"1846\" style=\"margin-top:24px;\"\u003e\u003cstrong data-start=\"1804\" data-end=\"1846\"\u003eWhy Choose Siemens 6SL3000-0HE21-0AA0?\u003c\/strong\u003e\u003c\/h3\u003e \u003cul data-start=\"1848\" data-end=\"2060\"\u003e \u003cli data-start=\"1848\" data-end=\"1893\"\u003e \u003cp data-start=\"1850\" data-end=\"1893\"\u003eEnhances drive protection and reliability\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1894\" data-end=\"1926\"\u003e \u003cp data-start=\"1896\" data-end=\"1926\"\u003eMinimizes power disturbances\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1927\" data-end=\"1966\"\u003e \u003cp data-start=\"1929\" data-end=\"1966\"\u003eSimple installation and integration\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"1967\" data-end=\"2012\"\u003e \u003cp data-start=\"1969\" data-end=\"2012\"\u003eBacked by Siemens quality and engineering\u003c\/p\u003e \u003c\/li\u003e \u003cli data-start=\"2013\" data-end=\"2060\"\u003e \u003cp data-start=\"2015\" data-end=\"2060\"\u003eEssential for stable, long-life drive systems\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 data-start=\"2062\" data-end=\"2079\" style=\"margin-top:24px;\"\u003e\u003cstrong data-start=\"2066\" data-end=\"2079\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"2081\" data-end=\"2219\"\u003eOptimize and protect your SINAMICS drive system with the Siemens 6SL3000-0HE21-0AA0 line reactor — designed for performance and longevity.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":41989862359086,"sku":"6SL3000-0HE21-0AA0","price":698.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/6sl3000-0he21-0aa0.webp?v=1767993115","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/siemens-6sl3000-0he21-0aa0-line-reactor-55kw","provider":"PLCVERSE","version":"1.0","type":"link"}