{"product_id":"beckhoff-kl4002-2-channel-0-10v-analog-output-terminal-12-bit-resolution","title":"Beckhoff KL4002","description":"\u003ch2\u003e\u003cstrong\u003eBeckhoff KL4002 | 2-Channel 0–10V Analog Output Terminal (12-Bit)\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eBeckhoff KL4002\u003c\/strong\u003e is a \u003cstrong\u003e2-channel analog output terminal\u003c\/strong\u003e crafted to \u003cstrong\u003egenerate voltage signals from 0 to 10V\u003c\/strong\u003e. With a \u003cstrong\u003e12-bit resolution\u003c\/strong\u003e, it guarantees \u003cstrong\u003eprecise and dependable voltage outputs\u003c\/strong\u003e, making it ideal for multiple applications in \u003cstrong\u003eindustrial automation and process control\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIts \u003cstrong\u003ecompact structure\u003c\/strong\u003e, \u003cstrong\u003eefficient operation\u003c\/strong\u003e, and \u003cstrong\u003ecompatibility with Beckhoff Bus Terminal systems\u003c\/strong\u003e make the \u003cstrong\u003eKL4002\u003c\/strong\u003e a top choice for applications needing \u003cstrong\u003eaccurate analog voltage outputs\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 Analog Output Channels\u003c\/strong\u003e – Provides \u003cstrong\u003e0 to 10V signal generation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Bit Resolution\u003c\/strong\u003e – Ensures \u003cstrong\u003eaccurate and stable voltage outputs\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e – Saves \u003cstrong\u003espace in control panels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators\u003c\/strong\u003e – Displays \u003cstrong\u003edata exchange status with the Bus Coupler\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e – Offers \u003cstrong\u003e500V isolation between K-bus and signal voltage\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KL4002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 0 to 10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Resistance:\u003c\/strong\u003e \u0026gt; 5 kΩ (short-circuit proof)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Error:\u003c\/strong\u003e \u0026lt; ±0.1% (relative to end value)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Time:\u003c\/strong\u003e ~1.5 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e 500V (K-bus\/signal voltage)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption (K-bus):\u003c\/strong\u003e Typically 75 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN Rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation \u0026amp; Process Control\u003c\/strong\u003e – Provides \u003cstrong\u003eprecise analog signal outputs\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator Control\u003c\/strong\u003e – Drives \u003cstrong\u003evalves, motors, and other actuators needing 0–10V inputs\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest \u0026amp; Measurement Systems\u003c\/strong\u003e – Supplies \u003cstrong\u003eaccurate voltage signals for testing purposes\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Automation\u003c\/strong\u003e – Controls \u003cstrong\u003eHVAC systems, lighting, and other building management systems\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCADA \u0026amp; PLC Systems\u003c\/strong\u003e – Integrates seamlessly with \u003cstrong\u003eBeckhoff Bus Terminal systems\u003c\/strong\u003e for \u003cstrong\u003eefficient control and monitoring\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eWhy Choose the Beckhoff KL4002?\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eReliable \u0026amp; High-Performance Analog Output Terminal\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompact \u0026amp; Durable for Industrial Applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEasy Integration with Beckhoff Bus Terminal Systems\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnsures Stable \u0026amp; Precise Voltage Output\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eFast shipping and worldwide delivery available.\u003c\/p\u003e","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":41629426384942,"sku":"KL4002","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/KL4002.webp?v=1763403845","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/beckhoff-kl4002-2-channel-0-10v-analog-output-terminal-12-bit-resolution","provider":"PLCVERSE","version":"1.0","type":"link"}