{"product_id":"allen-bradley-2085-iq32t-micro800-digital-input-module","title":"Allen-Bradley 2085-IQ32T","description":"\u003ch2 data-end=\"470\" data-start=\"407\" data-section-id=\"13zl9cw\"\u003e\u003cstrong data-end=\"470\" data-start=\"410\"\u003eAllen-Bradley 2085-IQ32T \u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-end=\"490\" data-start=\"472\" data-section-id=\"1dl56dh\"\u003e\u003cstrong data-end=\"488\" data-start=\"476\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"857\" data-start=\"491\"\u003eThe Allen-Bradley 2085-IQ32T is a \u003cstrong data-end=\"558\" data-start=\"525\"\u003eMicro800 digital input module\u003c\/strong\u003e designed to expand the I\/O capacity of Micro850 and Micro870 controllers. With 32 sink\/source inputs operating at 12\/24 V DC, it enables efficient signal acquisition from multiple field devices, ensuring reliable performance in industrial automation systems. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"881\" data-start=\"859\" data-section-id=\"1hx1w1i\"\u003e\u003cstrong data-end=\"879\" data-start=\"863\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1138\" data-start=\"882\"\u003e\n\u003cli data-end=\"925\" data-start=\"882\" data-section-id=\"1fykgyq\"\u003e\n\u003cp data-end=\"925\" data-start=\"884\"\u003eMicro800 digital input expansion module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"953\" data-start=\"926\" data-section-id=\"3igkxc\"\u003e\n\u003cp data-end=\"953\" data-start=\"928\"\u003e32-point digital inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"983\" data-start=\"954\" data-section-id=\"1w1y1fe\"\u003e\n\u003cp data-end=\"983\" data-start=\"956\"\u003eInput voltage: 12\/24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1027\" data-start=\"984\" data-section-id=\"1izrk7j\"\u003e\n\u003cp data-end=\"1027\" data-start=\"986\"\u003eSupports sinking and sourcing (PNP\/NPN)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1064\" data-start=\"1028\" data-section-id=\"i5dss2\"\u003e\n\u003cp data-end=\"1064\" data-start=\"1030\"\u003eHigh-density input configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1100\" data-start=\"1065\" data-section-id=\"ox4hah\"\u003e\n\u003cp data-end=\"1100\" data-start=\"1067\"\u003eLED indicators for input status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1138\" data-start=\"1101\" data-section-id=\"1i0oyyr\"\u003e\n\u003cp data-end=\"1138\" data-start=\"1103\"\u003eCompact design for control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1174\" data-start=\"1140\" data-section-id=\"1880me3\"\u003e\u003cstrong data-end=\"1172\" data-start=\"1144\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1676\" data-start=\"1175\"\u003e\n\u003cli data-end=\"1213\" data-start=\"1175\" data-section-id=\"a57k0l\"\u003e\n\u003cp data-end=\"1213\" data-start=\"1177\"\u003e\u003cstrong data-end=\"1200\" data-start=\"1177\"\u003eAllen-Bradley Code:\u003c\/strong\u003e 2085-IQ32T\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1260\" data-start=\"1214\" data-section-id=\"1e2gps0\"\u003e\n\u003cp data-end=\"1260\" data-start=\"1216\"\u003e\u003cstrong data-end=\"1227\" data-start=\"1216\"\u003eSeries:\u003c\/strong\u003e Micro800 (Micro850 \/ Micro870)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1289\" data-start=\"1261\" data-section-id=\"t4iv6j\"\u003e\n\u003cp data-end=\"1289\" data-start=\"1263\"\u003e\u003cstrong data-end=\"1284\" data-start=\"1263\"\u003eNumber of Inputs:\u003c\/strong\u003e 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1334\" data-start=\"1290\" data-section-id=\"167gl81\"\u003e\n\u003cp data-end=\"1334\" data-start=\"1292\"\u003e\u003cstrong data-end=\"1307\" data-start=\"1292\"\u003eInput Type:\u003c\/strong\u003e Sink\/Source (IEC Type 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1368\" data-start=\"1335\" data-section-id=\"1c9fjmi\"\u003e\n\u003cp data-end=\"1368\" data-start=\"1337\"\u003e\u003cstrong data-end=\"1355\" data-start=\"1337\"\u003eInput Voltage:\u003c\/strong\u003e 12\/24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1437\" data-start=\"1369\" data-section-id=\"17gfygu\"\u003e\n\u003cp data-end=\"1437\" data-start=\"1371\"\u003e\u003cstrong data-end=\"1393\" data-start=\"1371\"\u003ePower Dissipation:\u003c\/strong\u003e 7 W \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1480\" data-start=\"1438\" data-section-id=\"1s6io92\"\u003e\n\u003cp data-end=\"1480\" data-start=\"1440\"\u003e\u003cstrong data-end=\"1455\" data-start=\"1440\"\u003eBus System:\u003c\/strong\u003e Micro800 expansion I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1522\" data-start=\"1481\" data-section-id=\"15cb59n\"\u003e\n\u003cp data-end=\"1522\" data-start=\"1483\"\u003e\u003cstrong data-end=\"1496\" data-start=\"1483\"\u003eMounting:\u003c\/strong\u003e DIN rail or panel mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1554\" data-start=\"1523\" data-section-id=\"18a20oa\"\u003e\n\u003cp data-end=\"1554\" data-start=\"1525\"\u003e\u003cstrong data-end=\"1547\" data-start=\"1525\"\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1640\" data-start=\"1555\" data-section-id=\"9we6aj\"\u003e\n\u003cp data-end=\"1640\" data-start=\"1557\"\u003e\u003cstrong data-end=\"1583\" data-start=\"1557\"\u003eOperating Temperature:\u003c\/strong\u003e –20 °C to +65 °C \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1676\" data-start=\"1641\" data-section-id=\"qnkzo0\"\u003e\n\u003cp data-end=\"1676\" data-start=\"1643\"\u003e\u003cstrong data-end=\"1662\" data-start=\"1643\"\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1700\" data-start=\"1678\" data-section-id=\"xdxar3\"\u003e\u003cstrong data-end=\"1698\" data-start=\"1682\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1828\" data-start=\"1701\"\u003e\n\u003cli data-end=\"1723\" data-start=\"1701\" data-section-id=\"fa4uxh\"\u003e\n\u003cp data-end=\"1723\" data-start=\"1703\"\u003eMachine automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1753\" data-start=\"1724\" data-section-id=\"1icdun1\"\u003e\n\u003cp data-end=\"1753\" data-start=\"1726\"\u003eMaterial handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1777\" data-start=\"1754\" data-section-id=\"10batxa\"\u003e\n\u003cp data-end=\"1777\" data-start=\"1756\"\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1800\" data-start=\"1778\" data-section-id=\"r1uzu0\"\u003e\n\u003cp data-end=\"1800\" data-start=\"1780\"\u003eProcess monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1828\" data-start=\"1801\" data-section-id=\"9qjzb7\"\u003e\n\u003cp data-end=\"1828\" data-start=\"1803\"\u003eDistributed I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1876\" data-start=\"1830\" data-section-id=\"adptfz\"\u003e\u003cstrong data-end=\"1874\" data-start=\"1834\"\u003eWhy Choose Allen-Bradley 2085-IQ32T?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2075\" data-start=\"1877\"\u003e\n\u003cli data-end=\"1925\" data-start=\"1877\" data-section-id=\"19m5pal\"\u003e\n\u003cp data-end=\"1925\" data-start=\"1879\"\u003eHigh-density input expansion in compact form\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1964\" data-start=\"1926\" data-section-id=\"ifwng9\"\u003e\n\u003cp data-end=\"1964\" data-start=\"1928\"\u003eFlexible sink\/source compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2024\" data-start=\"1965\" data-section-id=\"1e2iasa\"\u003e\n\u003cp data-end=\"2024\" data-start=\"1967\"\u003eReliable signal acquisition for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2075\" data-start=\"2025\" data-section-id=\"vv8jot\"\u003e\n\u003cp data-end=\"2075\" data-start=\"2027\"\u003eSeamless integration with Micro800 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2096\" data-start=\"2077\" data-section-id=\"9pqy2m\"\u003e\u003cstrong data-end=\"2094\" data-start=\"2081\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2215\" data-start=\"2097\"\u003eExpand your control system with the Allen-Bradley 2085-IQ32T — efficient, reliable, and built for scalable automation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":42189815676974,"sku":"2085-IQ32T","price":336.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/2085-IQ32T_0c260939-6cdf-4d97-9d46-2faa4915cf3c.webp?v=1774317483","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/allen-bradley-2085-iq32t-micro800-digital-input-module","provider":"PLCVERSE","version":"1.0","type":"link"}