{"product_id":"abb-ssr10m","title":"ABB SSR10M","description":"\u003ch1 data-start=\"83\" data-end=\"123\"\u003e\u003cstrong data-start=\"85\" data-end=\"121\"\u003eABB SSR10M | Safety Relay Module\u003c\/strong\u003e\u003c\/h1\u003e \u003ch2 data-start=\"336\" data-end=\"353\"\u003e\u003cstrong data-start=\"339\" data-end=\"351\"\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e \u003cp data-start=\"354\" data-end=\"779\"\u003eThe \u003cstrong data-start=\"358\" data-end=\"372\"\u003eABB SSR10M\u003c\/strong\u003e is a \u003cstrong data-start=\"378\" data-end=\"401\"\u003esafety relay module\u003c\/strong\u003e created to improve the protection of industrial control systems. It ensures \u003cstrong data-start=\"481\" data-end=\"500\"\u003esafe monitoring\u003c\/strong\u003e of emergency stop buttons, safety gates, and other safety devices, offering \u003cstrong data-start=\"577\" data-end=\"597\"\u003ehigh reliability\u003c\/strong\u003e and \u003cstrong data-start=\"602\" data-end=\"625\"\u003efast response times\u003c\/strong\u003e. The SSR10M is designed for \u003cstrong data-start=\"654\" data-end=\"674\"\u003eeasy integration\u003c\/strong\u003e into automation systems, supporting operational safety in compliance with industry standards.\u003c\/p\u003e \u003ch2 data-start=\"781\" data-end=\"802\"\u003e\u003cstrong data-start=\"784\" data-end=\"800\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"803\" data-end=\"1221\"\u003e \u003cli data-start=\"803\" data-end=\"828\"\u003e \u003cstrong data-start=\"805\" data-end=\"815\"\u003eModel:\u003c\/strong\u003e ABB SSR10M\u003c\/li\u003e \u003cli data-start=\"829\" data-end=\"901\"\u003e \u003cstrong data-start=\"831\" data-end=\"844\"\u003eFunction:\u003c\/strong\u003e Safety relay module for industrial safety applications\u003c\/li\u003e \u003cli data-start=\"902\" data-end=\"977\"\u003e \u003cstrong data-start=\"904\" data-end=\"923\"\u003eCompact Design:\u003c\/strong\u003e Space-saving module for efficient panel integration\u003c\/li\u003e \u003cli data-start=\"978\" data-end=\"1059\"\u003e \u003cstrong data-start=\"980\" data-end=\"1003\"\u003eFast Response Time:\u003c\/strong\u003e Ensures immediate reaction to safety circuit failures\u003c\/li\u003e \u003cli data-start=\"1060\" data-end=\"1120\"\u003e \u003cstrong data-start=\"1062\" data-end=\"1081\"\u003eLED Indicators:\u003c\/strong\u003e Provides real-time status monitoring\u003c\/li\u003e \u003cli data-start=\"1121\" data-end=\"1221\"\u003e \u003cstrong data-start=\"1123\" data-end=\"1150\"\u003eMultiple Input Options:\u003c\/strong\u003e Compatible with safety switches, light curtains, and emergency stops\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1223\" data-end=\"1253\"\u003e\u003cstrong data-start=\"1226\" data-end=\"1251\"\u003eTechnical Information\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1254\" data-end=\"1581\"\u003e \u003cli data-start=\"1254\" data-end=\"1288\"\u003e \u003cstrong data-start=\"1256\" data-end=\"1275\"\u003eSupply Voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1276\" data-end=\"1286\"\u003e24V DC\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1289\" data-end=\"1352\"\u003e \u003cstrong data-start=\"1291\" data-end=\"1309\"\u003eRelay Outputs:\u003c\/strong\u003e \u003cstrong data-start=\"1310\" data-end=\"1350\"\u003e2 Normally Open (NO) safety contacts\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1353\" data-end=\"1386\"\u003e \u003cstrong data-start=\"1355\" data-end=\"1373\"\u003eResponse Time:\u003c\/strong\u003e \u003cstrong data-start=\"1374\" data-end=\"1384\"\u003e\u0026lt;20 ms\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1387\" data-end=\"1442\"\u003e \u003cstrong data-start=\"1389\" data-end=\"1421\"\u003eOperating Temperature Range:\u003c\/strong\u003e \u003cstrong data-start=\"1422\" data-end=\"1440\"\u003e-25°C to +55°C\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1443\" data-end=\"1487\"\u003e \u003cstrong data-start=\"1445\" data-end=\"1463\"\u003eMounting Type:\u003c\/strong\u003e \u003cstrong data-start=\"1464\" data-end=\"1485\"\u003eDIN rail mounting\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1488\" data-end=\"1581\"\u003e \u003cstrong data-start=\"1490\" data-end=\"1515\"\u003eStandards Compliance:\u003c\/strong\u003e \u003cstrong data-start=\"1516\" data-end=\"1533\"\u003eIEC 60947-5-1\u003c\/strong\u003e, \u003cstrong data-start=\"1535\" data-end=\"1550\"\u003eISO 13849-1\u003c\/strong\u003e, \u003cstrong data-start=\"1552\" data-end=\"1561\"\u003eSIL 3\u003c\/strong\u003e, \u003cstrong data-start=\"1563\" data-end=\"1579\"\u003eCE certified\u003c\/strong\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1583\" data-end=\"1604\"\u003e\u003cstrong data-start=\"1586\" data-end=\"1602\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1605\" data-end=\"1949\"\u003e \u003cli data-start=\"1605\" data-end=\"1702\"\u003e \u003cstrong data-start=\"1607\" data-end=\"1637\"\u003eEmergency Stop Monitoring:\u003c\/strong\u003e Ensures reliable shutdown of machinery in emergency situations\u003c\/li\u003e \u003cli data-start=\"1703\" data-end=\"1785\"\u003e \u003cstrong data-start=\"1705\" data-end=\"1729\"\u003eSafety Gate Control:\u003c\/strong\u003e Monitors interlocking devices for operator protection\u003c\/li\u003e \u003cli data-start=\"1786\" data-end=\"1862\"\u003e \u003cstrong data-start=\"1788\" data-end=\"1814\"\u003eLight Curtain Systems:\u003c\/strong\u003e Enhances safety in automated production lines\u003c\/li\u003e \u003cli data-start=\"1863\" data-end=\"1949\"\u003e \u003cstrong data-start=\"1865\" data-end=\"1893\"\u003eMachine Safety Circuits:\u003c\/strong\u003e Ensures compliance with industrial safety regulations\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1951\" data-end=\"1968\"\u003e\u003cstrong data-start=\"1954\" data-end=\"1966\"\u003eBenefits\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1969\" data-end=\"2415\"\u003e \u003cli data-start=\"1969\" data-end=\"2048\"\u003e \u003cstrong data-start=\"1971\" data-end=\"1991\"\u003eEnhanced Safety:\u003c\/strong\u003e Ensures secure monitoring of critical safety functions\u003c\/li\u003e \u003cli data-start=\"2049\" data-end=\"2130\"\u003e \u003cstrong data-start=\"2051\" data-end=\"2073\"\u003eEasy Installation:\u003c\/strong\u003e Compact design allows for quick and simple integration\u003c\/li\u003e \u003cli data-start=\"2131\" data-end=\"2228\"\u003e \u003cstrong data-start=\"2133\" data-end=\"2158\"\u003eReliable Performance:\u003c\/strong\u003e High-speed response ensures minimal risk in industrial environments\u003c\/li\u003e \u003cli data-start=\"2229\" data-end=\"2323\"\u003e \u003cstrong data-start=\"2231\" data-end=\"2256\"\u003eStandards Compliance:\u003c\/strong\u003e Meets international safety regulations for industrial automation\u003c\/li\u003e \u003cli data-start=\"2324\" data-end=\"2415\"\u003e \u003cstrong data-start=\"2326\" data-end=\"2351\"\u003eFlexible Integration:\u003c\/strong\u003e Compatible with various safety devices and automation systems\u003c\/li\u003e \u003c\/ul\u003e \u003cp data-start=\"2417\" data-end=\"2639\"\u003eThe \u003cstrong data-start=\"2421\" data-end=\"2435\"\u003eABB SSR10M\u003c\/strong\u003e is a dependable solution for industrial \u003cstrong data-start=\"2476\" data-end=\"2497\"\u003esafety monitoring\u003c\/strong\u003e, offering \u003cstrong data-start=\"2508\" data-end=\"2533\"\u003eefficient performance\u003c\/strong\u003e and \u003cstrong data-start=\"2538\" data-end=\"2574\"\u003ecompliance with safety standards\u003c\/strong\u003e to protect personnel and equipment in automation environments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42024284946478,"sku":"SSR10M","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/SSR10M.webp?v=1769096139","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/abb-ssr10m","provider":"PLCVERSE","version":"1.0","type":"link"}