{"product_id":"abb-s203-c6","title":"ABB S203-C6","description":"\u003ch1 data-start=\"82\" data-end=\"127\"\u003e\u003cstrong data-start=\"84\" data-end=\"127\"\u003eABB S203-C6 | Miniature Circuit Breaker\u003c\/strong\u003e\u003c\/h1\u003e \u003ch2 data-start=\"343\" data-end=\"360\"\u003e\u003cstrong data-start=\"346\" data-end=\"358\"\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e \u003cp data-start=\"361\" data-end=\"878\"\u003eThe \u003cstrong data-start=\"365\" data-end=\"380\"\u003eABB S203-C6\u003c\/strong\u003e is a \u003cstrong data-start=\"386\" data-end=\"421\"\u003eminiature circuit breaker (MCB)\u003c\/strong\u003e crafted to protect electrical circuits from \u003cstrong data-start=\"482\" data-end=\"494\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-start=\"499\" data-end=\"516\"\u003eshort circuit\u003c\/strong\u003e incidents. This breaker suits \u003cstrong data-start=\"562\" data-end=\"577\"\u003eresidential\u003c\/strong\u003e, \u003cstrong data-start=\"579\" data-end=\"593\"\u003ecommercial\u003c\/strong\u003e, and \u003cstrong data-start=\"599\" data-end=\"613\"\u003eindustrial\u003c\/strong\u003e settings, providing reliable protection with a \u003cstrong data-start=\"664\" data-end=\"682\"\u003ecompact design\u003c\/strong\u003e and \u003cstrong data-start=\"687\" data-end=\"713\"\u003ehigh breaking capacity\u003c\/strong\u003e. It is ideal for \u003cstrong data-start=\"733\" data-end=\"754\"\u003eDIN rail mounting\u003c\/strong\u003e in \u003cstrong data-start=\"758\" data-end=\"776\"\u003econtrol panels\u003c\/strong\u003e and \u003cstrong data-start=\"781\" data-end=\"804\"\u003edistribution boards\u003c\/strong\u003e, ensuring safety while conserving space in electrical setups.\u003c\/p\u003e \u003ch2 data-start=\"880\" data-end=\"901\"\u003e\u003cstrong data-start=\"883\" data-end=\"899\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"902\" data-end=\"1308\"\u003e \u003cli data-start=\"902\" data-end=\"928\"\u003e \u003cstrong data-start=\"904\" data-end=\"914\"\u003eModel:\u003c\/strong\u003e ABB S203-C6\u003c\/li\u003e \u003cli data-start=\"929\" data-end=\"1018\"\u003e \u003cstrong data-start=\"931\" data-end=\"944\"\u003eFunction:\u003c\/strong\u003e \u003cstrong data-start=\"945\" data-end=\"974\"\u003eMiniature circuit breaker\u003c\/strong\u003e for overload and short circuit protection\u003c\/li\u003e \u003cli data-start=\"1019\" data-end=\"1048\"\u003e \u003cstrong data-start=\"1021\" data-end=\"1039\"\u003eRated Current:\u003c\/strong\u003e \u003cstrong data-start=\"1040\" data-end=\"1046\"\u003e6A\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1049\" data-end=\"1084\"\u003e \u003cstrong data-start=\"1051\" data-end=\"1070\"\u003eVoltage Rating:\u003c\/strong\u003e \u003cstrong data-start=\"1071\" data-end=\"1082\"\u003e230V AC\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1085\" data-end=\"1119\"\u003e \u003cstrong data-start=\"1087\" data-end=\"1109\"\u003eBreaking Capacity:\u003c\/strong\u003e \u003cstrong data-start=\"1110\" data-end=\"1117\"\u003e6kA\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1120\" data-end=\"1214\"\u003e \u003cstrong data-start=\"1122\" data-end=\"1154\"\u003eThermal Magnetic Protection:\u003c\/strong\u003e Offers protection from \u003cstrong data-start=\"1178\" data-end=\"1190\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-start=\"1195\" data-end=\"1212\"\u003eshort circuit\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1215\" data-end=\"1308\"\u003e \u003cstrong data-start=\"1217\" data-end=\"1236\"\u003eCompact Design:\u003c\/strong\u003e Easily integrates into \u003cstrong data-start=\"1260\" data-end=\"1280\"\u003eDIN rail systems\u003c\/strong\u003e and \u003cstrong data-start=\"1285\" data-end=\"1308\"\u003edistribution boards\u003c\/strong\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1310\" data-end=\"1340\"\u003e\u003cstrong data-start=\"1313\" data-end=\"1338\"\u003eTechnical Information\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1341\" data-end=\"1620\"\u003e \u003cli data-start=\"1341\" data-end=\"1370\"\u003e \u003cstrong data-start=\"1343\" data-end=\"1361\"\u003eRated Current:\u003c\/strong\u003e \u003cstrong data-start=\"1362\" data-end=\"1368\"\u003e6A\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1371\" data-end=\"1405\"\u003e \u003cstrong data-start=\"1373\" data-end=\"1391\"\u003eRated Voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1392\" data-end=\"1403\"\u003e230V AC\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1406\" data-end=\"1440\"\u003e \u003cstrong data-start=\"1408\" data-end=\"1430\"\u003eBreaking Capacity:\u003c\/strong\u003e \u003cstrong data-start=\"1431\" data-end=\"1438\"\u003e6kA\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1441\" data-end=\"1476\"\u003e \u003cstrong data-start=\"1443\" data-end=\"1463\"\u003eNumber of Poles:\u003c\/strong\u003e \u003cstrong data-start=\"1464\" data-end=\"1474\"\u003e1 Pole\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1477\" data-end=\"1521\"\u003e \u003cstrong data-start=\"1479\" data-end=\"1497\"\u003eMounting Type:\u003c\/strong\u003e \u003cstrong data-start=\"1498\" data-end=\"1519\"\u003eDIN rail mounting\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1522\" data-end=\"1566\"\u003e \u003cstrong data-start=\"1524\" data-end=\"1548\"\u003eStandard Compliance:\u003c\/strong\u003e \u003cstrong data-start=\"1549\" data-end=\"1564\"\u003eIEC 60898-1\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1567\" data-end=\"1620\"\u003e \u003cstrong data-start=\"1569\" data-end=\"1601\"\u003eOperating Temperature Range:\u003c\/strong\u003e \u003cstrong data-start=\"1602\" data-end=\"1620\"\u003e-25°C to +60°C\u003c\/strong\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1622\" data-end=\"1643\"\u003e\u003cstrong data-start=\"1625\" data-end=\"1641\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1644\" data-end=\"2149\"\u003e \u003cli data-start=\"1644\" data-end=\"1759\"\u003e \u003cstrong data-start=\"1646\" data-end=\"1676\"\u003eResidential Installations:\u003c\/strong\u003e Ensures reliable protection for electrical circuits in homes and small buildings\u003c\/li\u003e \u003cli data-start=\"1760\" data-end=\"1854\"\u003e \u003cstrong data-start=\"1762\" data-end=\"1785\"\u003eCommercial Systems:\u003c\/strong\u003e Provides optimal protection in commercial electrical installations\u003c\/li\u003e \u003cli data-start=\"1855\" data-end=\"1955\"\u003e \u003cstrong data-start=\"1857\" data-end=\"1885\"\u003eIndustrial Applications:\u003c\/strong\u003e Safeguards electrical circuits and equipment in industrial settings\u003c\/li\u003e \u003cli data-start=\"1956\" data-end=\"2045\"\u003e \u003cstrong data-start=\"1958\" data-end=\"1977\"\u003eControl Panels:\u003c\/strong\u003e Perfect for use in \u003cstrong data-start=\"1997\" data-end=\"2015\"\u003econtrol panels\u003c\/strong\u003e to protect critical systems\u003c\/li\u003e \u003cli data-start=\"2046\" data-end=\"2149\"\u003e \u003cstrong data-start=\"2048\" data-end=\"2072\"\u003eDistribution Boards:\u003c\/strong\u003e Ideal for protection in \u003cstrong data-start=\"2097\" data-end=\"2120\"\u003edistribution boards\u003c\/strong\u003e and electrical installations\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"2151\" data-end=\"2168\"\u003e\u003cstrong data-start=\"2154\" data-end=\"2166\"\u003eBenefits\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"2169\" data-end=\"2597\"\u003e \u003cli data-start=\"2169\" data-end=\"2251\"\u003e \u003cstrong data-start=\"2171\" data-end=\"2195\"\u003eReliable Protection:\u003c\/strong\u003e Safeguards against \u003cstrong data-start=\"2215\" data-end=\"2227\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-start=\"2232\" data-end=\"2249\"\u003eshort circuit\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"2252\" data-end=\"2343\"\u003e \u003cstrong data-start=\"2254\" data-end=\"2274\"\u003eSpace-Efficient:\u003c\/strong\u003e \u003cstrong data-start=\"2275\" data-end=\"2293\"\u003eCompact design\u003c\/strong\u003e for integration into systems with limited space\u003c\/li\u003e \u003cli data-start=\"2344\" data-end=\"2431\"\u003e \u003cstrong data-start=\"2346\" data-end=\"2366\"\u003eEnhanced Safety:\u003c\/strong\u003e Complies with \u003cstrong data-start=\"2381\" data-end=\"2396\"\u003eIEC 60898-1\u003c\/strong\u003e for safe and reliable protection\u003c\/li\u003e \u003cli data-start=\"2432\" data-end=\"2518\"\u003e \u003cstrong data-start=\"2434\" data-end=\"2446\"\u003eDurable:\u003c\/strong\u003e Designed for \u003cstrong data-start=\"2460\" data-end=\"2476\"\u003elong-lasting\u003c\/strong\u003e performance in challenging environments\u003c\/li\u003e \u003cli data-start=\"2519\" data-end=\"2597\"\u003e \u003cstrong data-start=\"2521\" data-end=\"2544\"\u003eQuick Installation:\u003c\/strong\u003e Simple \u003cstrong data-start=\"2552\" data-end=\"2573\"\u003eDIN rail mounting\u003c\/strong\u003e for fast and easy setup\u003c\/li\u003e \u003c\/ul\u003e \u003cp data-start=\"2599\" data-end=\"2777\"\u003eThe \u003cstrong data-start=\"2603\" data-end=\"2618\"\u003eABB S203-C6\u003c\/strong\u003e is a reliable and \u003cstrong data-start=\"2637\" data-end=\"2659\"\u003eefficient solution\u003c\/strong\u003e for protecting electrical circuits, offering \u003cstrong data-start=\"2705\" data-end=\"2723\"\u003emaximum safety\u003c\/strong\u003e and \u003cstrong data-start=\"2728\" data-end=\"2752\"\u003eease of installation\u003c\/strong\u003e in various applications.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42024284880942,"sku":"S203-C6","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/S203-C6.webp?v=1769096136","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/abb-s203-c6","provider":"PLCVERSE","version":"1.0","type":"link"}