{"product_id":"abb-s202-b6","title":"ABB S202-B6","description":"\u003ch1 data-start=\"82\" data-end=\"135\"\u003e\u003cstrong data-start=\"84\" data-end=\"133\"\u003eABB S202-B6 | Miniature Circuit Breaker (MCB)\u003c\/strong\u003e\u003c\/h1\u003e \u003ch2 data-start=\"350\" data-end=\"367\"\u003e\u003cstrong data-start=\"353\" data-end=\"365\"\u003eOverview\u003c\/strong\u003e\u003c\/h2\u003e \u003cp data-start=\"368\" data-end=\"928\"\u003eThe \u003cstrong data-start=\"372\" data-end=\"387\"\u003eABB S202-B6\u003c\/strong\u003e is a \u003cstrong data-start=\"393\" data-end=\"428\"\u003eminiature circuit breaker (MCB)\u003c\/strong\u003e engineered to ensure dependable defense against \u003cstrong data-start=\"477\" data-end=\"489\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-start=\"494\" data-end=\"511\"\u003eshort circuit\u003c\/strong\u003e incidents in \u003cstrong data-start=\"526\" data-end=\"541\"\u003eresidential\u003c\/strong\u003e and \u003cstrong data-start=\"546\" data-end=\"579\"\u003ecommercial electrical systems\u003c\/strong\u003e. With a \u003cstrong data-start=\"588\" data-end=\"608\"\u003e6A rated current\u003c\/strong\u003e, it suits circuits needing moderate protection. The \u003cstrong data-start=\"670\" data-end=\"681\"\u003eS202-B6\u003c\/strong\u003e boasts a \u003cstrong data-start=\"693\" data-end=\"711\"\u003ecompact design\u003c\/strong\u003e and is \u003cstrong data-start=\"719\" data-end=\"739\"\u003eDIN rail mounted\u003c\/strong\u003e, simplifying integration into \u003cstrong data-start=\"774\" data-end=\"792\"\u003econtrol panels\u003c\/strong\u003e and \u003cstrong data-start=\"797\" data-end=\"820\"\u003edistribution boards\u003c\/strong\u003e. It offers \u003cstrong data-start=\"833\" data-end=\"857\"\u003eefficient protection\u003c\/strong\u003e and \u003cstrong data-start=\"862\" data-end=\"887\"\u003elong-term reliability\u003c\/strong\u003e for circuits with moderate power demands.\u003c\/p\u003e \u003ch2 data-start=\"930\" data-end=\"951\"\u003e\u003cstrong data-start=\"933\" data-end=\"949\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"952\" data-end=\"1444\"\u003e \u003cli data-start=\"952\" data-end=\"978\"\u003e \u003cstrong data-start=\"954\" data-end=\"964\"\u003eModel:\u003c\/strong\u003e ABB S202-B6\u003c\/li\u003e \u003cli data-start=\"979\" data-end=\"1074\"\u003e \u003cstrong data-start=\"981\" data-end=\"994\"\u003eFunction:\u003c\/strong\u003e \u003cstrong data-start=\"995\" data-end=\"1030\"\u003eMiniature circuit breaker (MCB)\u003c\/strong\u003e for overload and short circuit protection\u003c\/li\u003e \u003cli data-start=\"1075\" data-end=\"1100\"\u003e \u003cstrong data-start=\"1077\" data-end=\"1095\"\u003eRated Current:\u003c\/strong\u003e 6A\u003c\/li\u003e \u003cli data-start=\"1101\" data-end=\"1175\"\u003e \u003cstrong data-start=\"1103\" data-end=\"1121\"\u003eTripping Type:\u003c\/strong\u003e \u003cstrong data-start=\"1122\" data-end=\"1133\"\u003eB curve\u003c\/strong\u003e, for standard inrush current protection\u003c\/li\u003e \u003cli data-start=\"1176\" data-end=\"1216\"\u003e \u003cstrong data-start=\"1178\" data-end=\"1200\"\u003eBreaking Capacity:\u003c\/strong\u003e 6kA (at 230V)\u003c\/li\u003e \u003cli data-start=\"1217\" data-end=\"1299\"\u003e \u003cstrong data-start=\"1219\" data-end=\"1238\"\u003eCompact Design:\u003c\/strong\u003e Space-saving and easy to integrate into electrical systems\u003c\/li\u003e \u003cli data-start=\"1300\" data-end=\"1368\"\u003e \u003cstrong data-start=\"1302\" data-end=\"1324\"\u003eDIN Rail Mounting:\u003c\/strong\u003e Ensures quick installation and secure fit\u003c\/li\u003e \u003cli data-start=\"1369\" data-end=\"1444\"\u003e \u003cstrong data-start=\"1371\" data-end=\"1396\"\u003eReliable Performance:\u003c\/strong\u003e Fast tripping to protect circuits from faults\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1446\" data-end=\"1476\"\u003e\u003cstrong data-start=\"1449\" data-end=\"1474\"\u003eTechnical Information\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1477\" data-end=\"1755\"\u003e \u003cli data-start=\"1477\" data-end=\"1511\"\u003e \u003cstrong data-start=\"1479\" data-end=\"1497\"\u003eRated Voltage:\u003c\/strong\u003e 230\/400V AC\u003c\/li\u003e \u003cli data-start=\"1512\" data-end=\"1552\"\u003e \u003cstrong data-start=\"1514\" data-end=\"1536\"\u003eBreaking Capacity:\u003c\/strong\u003e 6kA (at 230V)\u003c\/li\u003e \u003cli data-start=\"1553\" data-end=\"1620\"\u003e \u003cstrong data-start=\"1555\" data-end=\"1573\"\u003eTripping Type:\u003c\/strong\u003e B (for standard inrush current applications)\u003c\/li\u003e \u003cli data-start=\"1621\" data-end=\"1656\"\u003e \u003cstrong data-start=\"1623\" data-end=\"1641\"\u003eMounting Type:\u003c\/strong\u003e \u003cstrong data-start=\"1642\" data-end=\"1654\"\u003eDIN rail\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1657\" data-end=\"1701\"\u003e \u003cstrong data-start=\"1659\" data-end=\"1685\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to 60°C\u003c\/li\u003e \u003cli data-start=\"1702\" data-end=\"1732\"\u003e \u003cstrong data-start=\"1704\" data-end=\"1725\"\u003eProtection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003cli data-start=\"1733\" data-end=\"1755\"\u003e \u003cstrong data-start=\"1735\" data-end=\"1746\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1757\" data-end=\"1778\"\u003e\u003cstrong data-start=\"1760\" data-end=\"1776\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1779\" data-end=\"2181\"\u003e \u003cli data-start=\"1779\" data-end=\"1866\"\u003e \u003cstrong data-start=\"1781\" data-end=\"1806\"\u003eResidential Circuits:\u003c\/strong\u003e Perfect for \u003cstrong data-start=\"1817\" data-end=\"1839\"\u003ehousehold circuits\u003c\/strong\u003e and \u003cstrong data-start=\"1844\" data-end=\"1864\"\u003esmall appliances\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1867\" data-end=\"1993\"\u003e \u003cstrong data-start=\"1869\" data-end=\"1894\"\u003eCommercial Buildings:\u003c\/strong\u003e Protects \u003cstrong data-start=\"1919\" data-end=\"1931\"\u003elighting\u003c\/strong\u003e and \u003cstrong data-start=\"1936\" data-end=\"1954\"\u003epower circuits\u003c\/strong\u003e in \u003cstrong data-start=\"1958\" data-end=\"1969\"\u003eoffices\u003c\/strong\u003e and \u003cstrong data-start=\"1974\" data-end=\"1991\"\u003eretail spaces\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1994\" data-end=\"2085\"\u003e \u003cstrong data-start=\"1996\" data-end=\"2020\"\u003eDistribution Panels:\u003c\/strong\u003e Suited for \u003cstrong data-start=\"2034\" data-end=\"2060\"\u003elow-power applications\u003c\/strong\u003e in \u003cstrong data-start=\"2064\" data-end=\"2083\"\u003econtrol systems\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"2086\" data-end=\"2181\"\u003e \u003cstrong data-start=\"2088\" data-end=\"2105\"\u003eHVAC Systems:\u003c\/strong\u003e Shields \u003cstrong data-start=\"2115\" data-end=\"2126\"\u003eheating\u003c\/strong\u003e, \u003cstrong data-start=\"2128\" data-end=\"2143\"\u003eventilation\u003c\/strong\u003e, and \u003cstrong data-start=\"2149\" data-end=\"2169\"\u003eair conditioning\u003c\/strong\u003e equipment\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"2183\" data-end=\"2200\"\u003e\u003cstrong data-start=\"2186\" data-end=\"2198\"\u003eBenefits\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"2201\" data-end=\"2552\"\u003e \u003cli data-start=\"2201\" data-end=\"2298\"\u003e \u003cstrong data-start=\"2203\" data-end=\"2227\"\u003eReliable Protection:\u003c\/strong\u003e Shields circuits from \u003cstrong data-start=\"2251\" data-end=\"2263\"\u003eoverload\u003c\/strong\u003e and \u003cstrong data-start=\"2268\" data-end=\"2285\"\u003eshort circuit\u003c\/strong\u003e issues\u003c\/li\u003e \u003cli data-start=\"2299\" data-end=\"2370\"\u003e \u003cstrong data-start=\"2301\" data-end=\"2327\"\u003eCompact and Efficient:\u003c\/strong\u003e Streamlined design for easy integration\u003c\/li\u003e \u003cli data-start=\"2371\" data-end=\"2443\"\u003e \u003cstrong data-start=\"2373\" data-end=\"2395\"\u003eEasy Installation:\u003c\/strong\u003e \u003cstrong data-start=\"2396\" data-end=\"2417\"\u003eDIN rail mounting\u003c\/strong\u003e simplifies setup\u003c\/li\u003e \u003cli data-start=\"2444\" data-end=\"2552\"\u003e \u003cstrong data-start=\"2446\" data-end=\"2475\"\u003eDurable and Long-Lasting:\u003c\/strong\u003e Built for \u003cstrong data-start=\"2489\" data-end=\"2511\"\u003ereliable operation\u003c\/strong\u003e in residential and commercial environments\u003c\/li\u003e \u003c\/ul\u003e \u003cp data-start=\"2554\" data-end=\"2733\"\u003eThe \u003cstrong data-start=\"2558\" data-end=\"2573\"\u003eABB S202-B6\u003c\/strong\u003e is a \u003cstrong data-start=\"2579\" data-end=\"2608\"\u003eminiature circuit breaker\u003c\/strong\u003e offering dependable protection for \u003cstrong data-start=\"2642\" data-end=\"2674\"\u003elow-power electrical systems\u003c\/strong\u003e, ensuring \u003cstrong data-start=\"2685\" data-end=\"2703\"\u003esafe operation\u003c\/strong\u003e and \u003cstrong data-start=\"2708\" data-end=\"2732\"\u003eefficient protection\u003c\/strong\u003e.\u003c\/p\u003e \u003chr\u003e \u003cp\u003e  \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42021906972718,"sku":"S202-B6","price":137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/S202-B6.webp?v=1769004135","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/abb-s202-b6","provider":"PLCVERSE","version":"1.0","type":"link"}