{"product_id":"abb-ce4t-10r-11","title":"ABB CE4T-10R-11","description":"\u003ch2 data-start=\"396\" data-end=\"471\"\u003e\u003cstrong data-start=\"399\" data-end=\"469\"\u003eABB CE4T-10R-11 | Auxiliary Contact Block, 1NO+1NC, Front Mounting\u003c\/strong\u003e\u003c\/h2\u003e \u003ch3 style=\"margin-top:24px;\" data-start=\"473\" data-end=\"492\"\u003e\u003cstrong data-start=\"477\" data-end=\"490\"\u003eOverview:\u003c\/strong\u003e\u003c\/h3\u003e \u003cp data-start=\"493\" data-end=\"839\"\u003eThe \u003cstrong data-start=\"497\" data-end=\"516\"\u003eABB CE4T-10R-11\u003c\/strong\u003e is a \u003cstrong data-start=\"522\" data-end=\"562\"\u003epremium auxiliary contact block\u003c\/strong\u003e crafted to \u003cstrong data-start=\"575\" data-end=\"621\"\u003eenhance ABB contactor performance\u003c\/strong\u003e with additional \u003cstrong data-start=\"646\" data-end=\"677\"\u003econtrol circuit connections\u003c\/strong\u003e. It includes \u003cstrong data-start=\"691\" data-end=\"752\"\u003e1 normally open (1NO) and 1 normally closed (1NC) contact\u003c\/strong\u003e, delivering \u003cstrong data-start=\"763\" data-end=\"797\"\u003econsistent switching capability\u003c\/strong\u003e in \u003cstrong data-start=\"801\" data-end=\"836\"\u003eindustrial control contexts\u003c\/strong\u003e.\u003c\/p\u003e \u003ch3 style=\"margin-top:24px;\" data-start=\"841\" data-end=\"864\"\u003e\u003cstrong data-start=\"845\" data-end=\"862\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e \u003cul data-start=\"865\" data-end=\"1394\"\u003e \u003cli data-start=\"865\" data-end=\"952\"\u003e \u003cstrong data-start=\"867\" data-end=\"902\"\u003e1NO + 1NC Contact Configuration\u003c\/strong\u003e – Offers flexible control circuit enhancement.\u003c\/li\u003e \u003cli data-start=\"953\" data-end=\"1042\"\u003e \u003cstrong data-start=\"955\" data-end=\"980\"\u003eFront Mounting Design\u003c\/strong\u003e – Facilitates swift installation on ABB contactors.\u003c\/li\u003e \u003cli data-start=\"1043\" data-end=\"1141\"\u003e \u003cstrong data-start=\"1045\" data-end=\"1080\"\u003eReliable Electrical Performance\u003c\/strong\u003e – Promises steady operation in industrial settings.\u003c\/li\u003e \u003cli data-start=\"1142\" data-end=\"1226\"\u003e \u003cstrong data-start=\"1144\" data-end=\"1168\"\u003eDurable Construction\u003c\/strong\u003e – Built to resist mechanical and electrical wear.\u003c\/li\u003e \u003cli data-start=\"1227\" data-end=\"1305\"\u003e \u003cstrong data-start=\"1229\" data-end=\"1255\"\u003eCompact \u0026amp; Space-Saving\u003c\/strong\u003e – Small footprint for optimal panel design.\u003c\/li\u003e \u003cli data-start=\"1306\" data-end=\"1394\"\u003e \u003cstrong data-start=\"1308\" data-end=\"1349\"\u003eComplies with International Standards\u003c\/strong\u003e – Aligns with \u003cstrong data-start=\"1358\" data-end=\"1391\"\u003eIEC and UL safety frameworks\u003c\/strong\u003e.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"margin-top:24px;\" data-start=\"1396\" data-end=\"1431\"\u003e\u003cstrong data-start=\"1400\" data-end=\"1429\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e \u003cul data-start=\"1432\" data-end=\"1972\"\u003e \u003cli data-start=\"1432\" data-end=\"1477\"\u003e \u003cstrong data-start=\"1434\" data-end=\"1451\"\u003eProduct Type:\u003c\/strong\u003e Auxiliary Contact Block\u003c\/li\u003e \u003cli data-start=\"1478\" data-end=\"1504\"\u003e \u003cstrong data-start=\"1480\" data-end=\"1490\"\u003eModel:\u003c\/strong\u003e CE4T-10R-11\u003c\/li\u003e \u003cli data-start=\"1505\" data-end=\"1583\"\u003e \u003cstrong data-start=\"1507\" data-end=\"1533\"\u003eContact Configuration:\u003c\/strong\u003e 1 Normally Open (1NO) + 1 Normally Closed (1NC)\u003c\/li\u003e \u003cli data-start=\"1584\" data-end=\"1621\"\u003e \u003cstrong data-start=\"1586\" data-end=\"1604\"\u003eMounting Type:\u003c\/strong\u003e Front Mounting\u003c\/li\u003e \u003cli data-start=\"1622\" data-end=\"1670\"\u003e \u003cstrong data-start=\"1624\" data-end=\"1654\"\u003eRated Operational Voltage:\u003c\/strong\u003e Up to 690V AC\u003c\/li\u003e \u003cli data-start=\"1671\" data-end=\"1744\"\u003e \u003cstrong data-start=\"1673\" data-end=\"1703\"\u003eRated Operational Current:\u003c\/strong\u003e Up to 10A (AC-15 utilization category)\u003c\/li\u003e \u003cli data-start=\"1745\" data-end=\"1806\"\u003e \u003cstrong data-start=\"1747\" data-end=\"1773\"\u003eMechanical Durability:\u003c\/strong\u003e Over \u003cstrong data-start=\"1779\" data-end=\"1804\"\u003e10 million operations\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1807\" data-end=\"1884\"\u003e \u003cstrong data-start=\"1809\" data-end=\"1835\"\u003eElectrical Durability:\u003c\/strong\u003e Over \u003cstrong data-start=\"1841\" data-end=\"1865\"\u003e1 million operations\u003c\/strong\u003e at rated current\u003c\/li\u003e \u003cli data-start=\"1885\" data-end=\"1930\"\u003e \u003cstrong data-start=\"1887\" data-end=\"1913\"\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +60°C\u003c\/li\u003e \u003cli data-start=\"1931\" data-end=\"1972\"\u003e \u003cstrong data-start=\"1933\" data-end=\"1952\"\u003eCertifications:\u003c\/strong\u003e IEC, UL, CE, RoHS\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"margin-top:24px;\" data-start=\"1974\" data-end=\"1997\"\u003e\u003cstrong data-start=\"1978\" data-end=\"1995\"\u003eApplications:\u003c\/strong\u003e\u003c\/h3\u003e \u003cul data-start=\"1998\" data-end=\"2391\"\u003e \u003cli data-start=\"1998\" data-end=\"2080\"\u003e \u003cstrong data-start=\"2000\" data-end=\"2029\"\u003eIndustrial Control Panels\u003c\/strong\u003e – Enhances control circuit functionality.\u003c\/li\u003e \u003cli data-start=\"2081\" data-end=\"2186\"\u003e \u003cstrong data-start=\"2083\" data-end=\"2114\"\u003eMotor Starters \u0026amp; Contactors\u003c\/strong\u003e – Provides auxiliary contacts for \u003cstrong data-start=\"2145\" data-end=\"2183\"\u003estatus signaling and control logic\u003c\/strong\u003e.\u003c\/li\u003e \u003cli data-start=\"2187\" data-end=\"2286\"\u003e \u003cstrong data-start=\"2189\" data-end=\"2221\"\u003eAutomation \u0026amp; Process Control\u003c\/strong\u003e – Ideal for \u003cstrong data-start=\"2232\" data-end=\"2283\"\u003emanufacturing, HVAC, and machinery operations\u003c\/strong\u003e.\u003c\/li\u003e \u003cli data-start=\"2287\" data-end=\"2391\"\u003e \u003cstrong data-start=\"2289\" data-end=\"2324\"\u003eElectrical Distribution Systems\u003c\/strong\u003e – Assists in additional \u003cstrong data-start=\"2347\" data-end=\"2388\"\u003emonitoring and interlocking tasks\u003c\/strong\u003e.\u003c\/li\u003e \u003c\/ul\u003e \u003cp data-start=\"2393\" data-end=\"2614\" data-is-last-node=\"\"\u003eThe \u003cstrong data-start=\"2397\" data-end=\"2416\"\u003eABB CE4T-10R-11\u003c\/strong\u003e auxiliary contact block is a \u003cstrong data-start=\"2446\" data-end=\"2467\"\u003ereliable choice\u003c\/strong\u003e for \u003cstrong data-start=\"2472\" data-end=\"2509\"\u003eimproving contactor function\u003c\/strong\u003e, ensuring \u003cstrong data-start=\"2520\" data-end=\"2567\"\u003eefficient and reliable electrical switching\u003c\/strong\u003e in \u003cstrong data-start=\"2571\" data-end=\"2613\"\u003eindustrial and commercial applications\u003c\/strong\u003e.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42016273137710,"sku":"CE4T-10R-11","price":74.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/CE4T-10R-11.webp?v=1768842719","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/abb-ce4t-10r-11","provider":"PLCVERSE","version":"1.0","type":"link"}