{"product_id":"6es7138-4fa05-0ab0-siemens-simatic-dp-electronics-module-f-et200s","title":"SIEMENS 6ES7138-4FA05-0AB0","description":"\u003ch2 data-start=\"99\" data-end=\"165\"\u003e\u003cstrong data-start=\"102\" data-end=\"163\"\u003eSIEMENS 6ES7138-4FA05-0AB0 | SIMATIC DP Electronic Module\u003c\/strong\u003e\u003c\/h2\u003e \u003ch2 data-start=\"483\" data-end=\"500\"\u003e\u003cstrong data-start=\"486\" data-end=\"498\"\u003eOVERVIEW\u003c\/strong\u003e\u003c\/h2\u003e \u003cp data-start=\"502\" data-end=\"910\"\u003eThe \u003cstrong data-start=\"506\" data-end=\"536\"\u003eSiemens 6ES7138-4FA05-0AB0\u003c\/strong\u003e is a \u003cstrong data-start=\"542\" data-end=\"576\"\u003efail-safe digital input module\u003c\/strong\u003e for the \u003cstrong data-start=\"585\" data-end=\"607\"\u003eET 200S I\/O system\u003c\/strong\u003e, delivering \u003cstrong data-start=\"618\" data-end=\"655\"\u003ereliable safety functions\u003c\/strong\u003e in \u003cstrong data-start=\"659\" data-end=\"697\"\u003eindustrial automation settings\u003c\/strong\u003e. Using \u003cstrong data-start=\"704\" data-end=\"731\"\u003ePROFIsafe communication\u003c\/strong\u003e, it guarantees \u003cstrong data-start=\"744\" data-end=\"787\"\u003esecure and accurate data transfer\u003c\/strong\u003e, making it ideal for \u003cstrong data-start=\"809\" data-end=\"840\"\u003esafety-critical applications\u003c\/strong\u003e in \u003cstrong data-start=\"844\" data-end=\"907\"\u003emachine automation, process control, and factory automation\u003c\/strong\u003e.\u003c\/p\u003e \u003ch2 data-start=\"912\" data-end=\"933\"\u003e\u003cstrong data-start=\"915\" data-end=\"931\"\u003eKEY FEATURES\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"935\" data-end=\"1418\"\u003e \u003cli data-start=\"935\" data-end=\"976\"\u003e \u003cstrong data-start=\"937\" data-end=\"947\"\u003eModel:\u003c\/strong\u003e Siemens 6ES7138-4FA05-0AB0\u003c\/li\u003e \u003cli data-start=\"977\" data-end=\"1008\"\u003e \u003cstrong data-start=\"979\" data-end=\"990\"\u003eSeries:\u003c\/strong\u003e SIMATIC ET 200S\u003c\/li\u003e \u003cli data-start=\"1009\" data-end=\"1057\"\u003e \u003cstrong data-start=\"1011\" data-end=\"1020\"\u003eType:\u003c\/strong\u003e \u003cstrong data-start=\"1021\" data-end=\"1055\"\u003eFail-Safe Digital Input Module\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1058\" data-end=\"1132\"\u003e \u003cstrong data-start=\"1060\" data-end=\"1071\"\u003eInputs:\u003c\/strong\u003e \u003cstrong data-start=\"1072\" data-end=\"1130\"\u003e4 fail-safe digital inputs (24V DC, PROFIsafe-capable)\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1133\" data-end=\"1192\"\u003e \u003cstrong data-start=\"1135\" data-end=\"1153\"\u003eCommunication:\u003c\/strong\u003e \u003cstrong data-start=\"1154\" data-end=\"1190\"\u003ePROFIsafe over PROFINET\/PROFIBUS\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1193\" data-end=\"1274\"\u003e \u003cstrong data-start=\"1195\" data-end=\"1212\"\u003eSafety Level:\u003c\/strong\u003e \u003cstrong data-start=\"1213\" data-end=\"1272\"\u003eCompliant with SIL 3 (IEC 61508) and PL e (ISO 13849-1)\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1275\" data-end=\"1351\"\u003e \u003cstrong data-start=\"1277\" data-end=\"1293\"\u003eDiagnostics:\u003c\/strong\u003e \u003cstrong data-start=\"1294\" data-end=\"1349\"\u003eComprehensive status and error diagnostics via LEDs\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1352\" data-end=\"1418\"\u003e \u003cstrong data-start=\"1354\" data-end=\"1372\"\u003eCompatibility:\u003c\/strong\u003e \u003cstrong data-start=\"1373\" data-end=\"1416\"\u003eDesigned for ET 200S modular I\/O system\u003c\/strong\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1420\" data-end=\"1450\"\u003e\u003cstrong data-start=\"1423\" data-end=\"1448\"\u003eTECHNICAL INFORMATION\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1452\" data-end=\"1909\"\u003e \u003cli data-start=\"1452\" data-end=\"1508\"\u003e \u003cstrong data-start=\"1454\" data-end=\"1475\"\u003eNumber of Inputs:\u003c\/strong\u003e \u003cstrong data-start=\"1476\" data-end=\"1506\"\u003e4 fail-safe digital inputs\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1509\" data-end=\"1569\"\u003e \u003cstrong data-start=\"1511\" data-end=\"1529\"\u003eInput Voltage:\u003c\/strong\u003e \u003cstrong data-start=\"1530\" data-end=\"1567\"\u003e24V DC (according to IEC 61131-2)\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1570\" data-end=\"1636\"\u003e \u003cstrong data-start=\"1572\" data-end=\"1592\"\u003eSafety Protocol:\u003c\/strong\u003e \u003cstrong data-start=\"1593\" data-end=\"1634\"\u003ePROFIsafe for fail-safe communication\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1637\" data-end=\"1707\"\u003e \u003cstrong data-start=\"1639\" data-end=\"1657\"\u003eResponse Time:\u003c\/strong\u003e \u003cstrong data-start=\"1658\" data-end=\"1705\"\u003eOptimized for fast safety signal processing\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1708\" data-end=\"1767\"\u003e \u003cstrong data-start=\"1710\" data-end=\"1725\"\u003eConnection:\u003c\/strong\u003e \u003cstrong data-start=\"1726\" data-end=\"1765\"\u003ePush-in terminals for secure wiring\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1768\" data-end=\"1817\"\u003e \u003cstrong data-start=\"1770\" data-end=\"1796\"\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong data-start=\"1797\" data-end=\"1815\"\u003e-20°C to +60°C\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"1818\" data-end=\"1909\"\u003e \u003cstrong data-start=\"1820\" data-end=\"1839\"\u003eCertifications:\u003c\/strong\u003e \u003cstrong data-start=\"1840\" data-end=\"1907\"\u003eSIL 3 (IEC 61508), PL e (ISO 13849-1), CE, UL, cUL, ATEX Zone 2\u003c\/strong\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"1911\" data-end=\"1932\"\u003e\u003cstrong data-start=\"1914\" data-end=\"1930\"\u003eAPPLICATIONS\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"1934\" data-end=\"2379\"\u003e \u003cli data-start=\"1934\" data-end=\"2027\"\u003e \u003cstrong data-start=\"1936\" data-end=\"1966\"\u003eIndustrial Safety Systems:\u003c\/strong\u003e \u003cstrong data-start=\"1967\" data-end=\"2025\"\u003eEnsures safe signal processing in manufacturing plants\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"2028\" data-end=\"2114\"\u003e \u003cstrong data-start=\"2030\" data-end=\"2051\"\u003eMachine Guarding:\u003c\/strong\u003e \u003cstrong data-start=\"2052\" data-end=\"2112\"\u003eUsed in emergency stop circuits and interlocking systems\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"2115\" data-end=\"2188\"\u003e \u003cstrong data-start=\"2117\" data-end=\"2140\"\u003eProcess Automation:\u003c\/strong\u003e \u003cstrong data-start=\"2141\" data-end=\"2186\"\u003eEnhances safety in hazardous environments\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"2189\" data-end=\"2283\"\u003e \u003cstrong data-start=\"2191\" data-end=\"2214\"\u003eFactory Automation:\u003c\/strong\u003e \u003cstrong data-start=\"2215\" data-end=\"2281\"\u003eIdeal for fail-safe integration in distributed control systems\u003c\/strong\u003e \u003c\/li\u003e \u003cli data-start=\"2284\" data-end=\"2379\"\u003e \u003cstrong data-start=\"2286\" data-end=\"2314\"\u003eCritical Infrastructure:\u003c\/strong\u003e \u003cstrong data-start=\"2315\" data-end=\"2377\"\u003eApplied in power plants, chemical processing, and robotics\u003c\/strong\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch2 data-start=\"2381\" data-end=\"2398\"\u003e\u003cstrong data-start=\"2384\" data-end=\"2396\"\u003eBENEFITS\u003c\/strong\u003e\u003c\/h2\u003e \u003cul data-start=\"2400\" data-end=\"2734\"\u003e \u003cli data-start=\"2400\" data-end=\"2472\"\u003e\u003cstrong data-start=\"2402\" data-end=\"2470\"\u003eFail-safe inputs ensure high reliability for safety applications\u003c\/strong\u003e\u003c\/li\u003e \u003cli data-start=\"2473\" data-end=\"2542\"\u003e\u003cstrong data-start=\"2475\" data-end=\"2540\"\u003ePROFIsafe communication minimizes risk of data loss or errors\u003c\/strong\u003e\u003c\/li\u003e \u003cli data-start=\"2543\" data-end=\"2611\"\u003e\u003cstrong data-start=\"2545\" data-end=\"2609\"\u003eCompact design for seamless integration into ET 200S systems\u003c\/strong\u003e\u003c\/li\u003e \u003cli data-start=\"2612\" data-end=\"2668\"\u003e\u003cstrong data-start=\"2614\" data-end=\"2666\"\u003eMeets highest safety standards (SIL 3, PL e)\u003c\/strong\u003e\u003c\/li\u003e \u003cli data-start=\"2669\" data-end=\"2734\"\u003e\u003cstrong data-start=\"2671\" data-end=\"2732\"\u003eEasy installation and diagnostics reduce maintenance time\u003c\/strong\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp data-start=\"2736\" data-end=\"2914\"\u003eThe \u003cstrong data-start=\"2740\" data-end=\"2770\"\u003eSiemens 6ES7138-4FA05-0AB0\u003c\/strong\u003e is a \u003cstrong data-start=\"2776\" data-end=\"2818\"\u003ereliable fail-safe input module\u003c\/strong\u003e, ensuring \u003cstrong data-start=\"2829\" data-end=\"2869\"\u003esafe and efficient signal processing\u003c\/strong\u003e in \u003cstrong data-start=\"2873\" data-end=\"2911\"\u003eindustrial automation environments\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":41635029286958,"sku":"6ES7138-4FA05-0AB0","price":304.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/6ES7138-4FA05-0AB0_4b516e34-58b1-4a7d-b392-71a529e99888.webp?v=1763572730","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/6es7138-4fa05-0ab0-siemens-simatic-dp-electronics-module-f-et200s","provider":"PLCVERSE","version":"1.0","type":"link"}