{"product_id":"1784-ktx-allen-bradley-isa-bus-pc-card-w-dh-dh485-rio","title":"Allen-Bradley 1784-KTX","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley 1784-KTX | DH+ and Remote I\/O Communication Interface Card\u003c\/strong\u003e\u003c\/h2\u003e \u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e \u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1784-KTX\u003c\/strong\u003e is a \u003cstrong\u003ePCI communication interface card\u003c\/strong\u003e designed to connect industrial PCs with \u003cstrong\u003eAllen-Bradley PLCs\u003c\/strong\u003e over \u003cstrong\u003eData Highway Plus (DH+)\u003c\/strong\u003e and \u003cstrong\u003eRemote I\/O networks\u003c\/strong\u003e. It's widely used in \u003cstrong\u003elegacy automation systems\u003c\/strong\u003e, providing a dependable way to integrate PCs with existing Rockwell Automation equipment for programming, monitoring, or SCADA applications.\u003c\/p\u003e \u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eNetwork Support:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp\u003eData Highway Plus (DH+)\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003eRemote I\/O (RIO)\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eBus Interface:\u003c\/strong\u003e ISA or PCI (depending on version)\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eCommunication Speed:\u003c\/strong\u003e 57.6 kbps, 115.2 kbps, or 230.4 kbps\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp\u003eAccess and communicate with PLC-5, SLC 500, and other legacy systems\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003eIntegrate with RSLogix 5, RSLogix 500, and RSLinx\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e Status indicators for network and card diagnostics\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eDriver Compatibility:\u003c\/strong\u003e Works with RSLinx and compatible Rockwell software\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 1784-KTX\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen-Bradley \/ Rockwell Automation\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eInterface:\u003c\/strong\u003e PCI (32-bit)\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eNetwork Types:\u003c\/strong\u003e DH+ and Remote I\/O\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eSupported Software:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e \u003cp\u003eRSLinx Classic\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003eRSLogix 5 \/ 500\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eOperating Systems:\u003c\/strong\u003e Windows-based systems (depending on driver support)\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 0°C to +60°C\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Standard PCI form factor\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Provided via PCI slot\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eLegacy PLC Programming:\u003c\/strong\u003e Access older PLC systems like PLC-5 and SLC 500\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eSCADA Integration:\u003c\/strong\u003e Connect industrial PCs to legacy DH+ networks\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eControl System Maintenance:\u003c\/strong\u003e Crucial for facilities using older Rockwell Automation equipment\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eWhy Choose the Allen-Bradley 1784-KTX?\u003c\/strong\u003e\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eReliable DH+ and RIO Communication\u003c\/strong\u003e for legacy Allen-Bradley systems\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eEssential for Maintenance and Troubleshooting\u003c\/strong\u003e in older networks\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eCompatible with Rockwell Software Tools\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cstrong\u003eProven Industrial-Grade Performance\u003c\/strong\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"margin-top:24px;\"\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e \u003cp\u003eFast shipping and worldwide delivery available.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":41638668795950,"sku":"1784-KTX","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/2791\/4798\/files\/1784KTX.png?v=1763765346","url":"https:\/\/qrh1h7-cr.myshopify.com\/products\/1784-ktx-allen-bradley-isa-bus-pc-card-w-dh-dh485-rio","provider":"PLCVERSE","version":"1.0","type":"link"}